Home·Solutions

Our Solutions

Precision-engineered solutions for solar monitoring, power control, and seamless communication.

01Plant Supervision

PC-based SCADA

Plant-wide supervision for large ground-mounted solar plants — live data, historical trends, alerts, reports and fault analysis in one on-premise dashboard, with remote monitoring built in.

◈
Live data & historical trends

Plant-wide supervision from a single PC-based workstation, with live data alongside full historical trend history for every connected device.

◈
Remote monitoring & control

Supervise and control plant equipment remotely, with the same on/off and time-based control tools used across eSenZ hardware.

◈
DG sync & zero export control

Built-in control tools for PV-DG synchronisation, zero export and export limits, alongside time-based operation.

◈
Alerts, reports & fault analysis

Configurable threshold alerts with automated reports and fault analysis to reduce downtime across large sites.

eSenZ PC-based SCADA dashboardPC-based SCADA

Specifications

Deployment
On-premise, Windows PC
Scope
Utility-scale ground-mounted plants
Data sources
Inverters, meters, sensors
Protocols
RS485 Modbus RTU / TCP
Control
DG sync, zero export, on/off, time-based
Enquire now ↗
02Power Limiter

ZED + DG Synch
Zero Export Device & PV-DG Synchronisation

ZED intelligently curtails excess solar generation to prevent reverse flow into the grid, while DG Synch seamlessly synchronises solar inverters with diesel generators — reducing fuel consumption and operational costs.

◈
Precision export control (ZED)

Real-time monitoring and dynamic throttling of inverter output to maintain zero net export to the grid.

◈
PV-DG synchronisation (DG Synch)

Smart loading algorithm maximises solar usage while DG sets handle the balance — cutting diesel consumption by up to 40%.

◈
ZED + DG Synch, combined

Run both together on one site: export stays at zero on-grid, and generation still shifts smartly to DG when solar can't cover the load.

◈
Outdoor-rated enclosure

IP65-protected enclosure engineered to withstand heat, dust, and heavy rainfall in demanding outdoor environments.

◈
Remote monitoring & alerts

Real-time status on the eSenZ portal with configurable threshold alerts via SMS and email.

eSenZ ZED Zero Export controllerPower Limiter

Specifications

Control mode
Active power curtailment
Response time
≥ 500 ms
Inverter brands
60+ supported
Protocols
RS485 Modbus RTU / TCP
Communication
4G, WiFi 2.4 GHz, LAN
Enquire now ↗
03Data Acquisition

Data Logger

A single device that consolidates RS485-based inverters, energy meters, weather sensors and BMS units into one unified cloud logging system — accessible from anywhere.

◈
Multi-brand inverter support

Compatible with 60+ inverter brands deployed across India — Solis, Sungrow, Sofar, Havells, SMA, Huawei, Growatt, Delta, Fronius and more.

◈
Multi-band connectivity in one device

4G, WiFi, Ethernet (LAN) and RS485 all supported on a single logger, so it stays connected regardless of what's available on site.

◈
Outdoor-rated enclosure

IP65-protected enclosure engineered to withstand heat, dust, and heavy rainfall in demanding outdoor environments.

◈
API & BMS integration

Supports seamless integration with third-party platforms, SCADA, and Building Management Systems via RS485 and open REST APIs.

◈
Remote monitoring & alerts

Real-time status on the eSenZ portal with configurable threshold alerts via SMS and email.

eSenZ Data Logger deviceData Logger

Specifications

Protocols
RS485 Modbus RTU / TCP
Communication
4G, WiFi 2.4 GHz, LAN
Analog inputs
Up to 3 (V) + 2 (I)
Relay output
1, for external relay
Data interval
≥5 min (configurable)
Enquire now ↗
04Communication

Wireless RS485 transceiver
/ OFC solutions

Eliminate costly and time-consuming cable runs across large solar sites with our wireless RS485 bridges and optical fibre converters — delivering reliable, interference-free communication.

◈
Wireless RS485 bridge (Air Link)

Transmit RS485 signals wirelessly over distances up to 1 km line-of-sight — eliminating trenching and long cable runs. See Air Link in detail.

◈
Optical fibre converter (Opti Link)

RS485 to fibre optic conversion for electrically isolated, interference-immune data transmission over up to 5 km. See Opti Link in detail.

◈
RS485 repeaters & splitters

Extend and branch RS485 bus networks without signal degradation — ideal for large multi-inverter arrays.

◈
Plug-and-play installation

No configuration required for most deployments — just connect and the network is established within seconds.

eSenZ wireless RS485 deviceWireless RS485

Specifications

Wireless range
Up to 1 km (LoS)
Baud rate
2400–115200 bps
OFC distance
Up to 5 km
Interface
RS485
Power
12 V DC
Enclosure
IP65, wall / DIN rail
Enquire now ↗

Have a project
in mind?

Our team is ready to help you choose the right solution and get your site live fast.